Immergas Mini boilers are the first generations of Mini boilers. On the control panel of boilers there are: a thermomanometer, a yellow light signaling the presence of a flame, a red light blocking the boiler and three control knobs: the main switch of the boiler and the switch of operating modes, resetting the lock; hot water temperature regulator; water temperature regulator in the heating system.
The Immergaz Mini board is intended for installation on coppers of Nike - with the open combustion chamber and Eolo - the closed chamber.
Immergas Mini boilers are phase-dependent gas boilers. If incorrectly plugged in - the boiler is blocked. It is necessary to turn the plug to the correct position, then remove the boiler from the lock by turning the main switch to the reset position. Boiler lock (red indicator light) does not always mean that the control board is failing. Probable causes can be: ignition blocking, overheating blocking - lack of water in the primary circuit, low circulation, pump blocking.