ROTEX A1BO27H Diverter Valve Actuator Head - Honeywell VC4012
Product Classification: Original
Drive with EPE control (single-pole switching).
When heat is required, the controller contact is closed, RLY1 tightens and closes the contact NO of switch SW3. This closes port B and opens port A. When A is fully open, the cam switch closes SW1 and opens SW2.
Once the heat demand has been covered, the controller contact is opened. RLY1 drops and the NC contact in SW3 is closed. If port A is completely closed, the cam closes SW2 and opens SW1. The valve is now ready for the next heat requirement.
In the event of a power failure, the valve remains in the current position for both types of actuators. When the power is turned back on, the valve responds to the regulator state.
• Suitable for changeover valve VC
• Power consumption: 4 W
• Protection class: IP40
• Insulation class: II
• Single-pole switched on
- Molex connector (6-pin connector on the side for cables with Molex connector)
-230 volts 50/60 Hz
Giersch: 071051183
Molexstecker: 071051183
Baxi : 243341
Sime : 6087303
Hermann: 2000803043
Suitable Model:
Rotex: GSU25F, A1BO20H, A1BG25, A1BG40, A1BO15e, A1BO20E, GSU535, GSU320, GSU35, GSU520, GSU530, A1BO27H, A1BO15H, GCU35, A1BO35e, A1BO35H, A1BO27e, GCU35F, GSU25
Remeha: Quinta25SOLO, Quinta10SOLO, Quinta30SOLO, W28C, W21C
Rapido: GAKW10E,GAKW30E,GAKW20E
Giersch: GiegaStarC20, GiegaStar11, GiegaStar31, GiegaStar21, GiegaStar20, GiegaStar10, GiegaStar30
Baxi: Combi 130 He, Combi 133 He Plus, Combi 80 He Plus, Combi 100 He Plus
Hermann: Eura Supermaster, Acquaplus, Comfort, Compact, Ecolaser, Eura, Eura Condensing, Eura Top, Eura Top Condensing, Laser, Master, Master inox, Polar, Spazio Due, Spazio Tre, Spazio Uno, Spazio Zero, Supermaster, Supermaster Ecoplus, Supermaster Inox, Supermicra System
Sime: Duetto 30BF